Table 1 Ventilator settings using ARDSNet low PEEP/FiO2 and transpulmonary end-expiratory pressure strategy

ARDSNet - Low PEEP/FiO2 Transpulmonary end-expiratory pressure (PL-exp)
FiO2 (%) PEEP (cm H2O) FiO2 PL-exp (cm H2O)
30 5 40 0
40 50
40 8 50 2
50 60
50 10 60 4
60 70
70 70 6
70 12 80
70 14 80 8
80 90
90 90 10
90 16 100
90 18
100 20–24